ATEN 4-Outlet Eco PDU Power Controller

PE4104

  • Local and remote power outlet control (On, Off, Power Cycle) by individual outlets
  • Power-on sequencing – users can set the power on sequence and delay time for each port to allow equipment to be turned on in a proper order
  • Works with web-based eco DC software
  • Remote power control via TCP/IP and a built in 10/100 Ethernet port

The ATEN Eco PDU PE4104 is an intelligent 4-outlet power controller designed to provide secure, centralized, and remote power management for IT equipment. Built for data centers, edge computing environments, retail applications, and digital signage deployments, the PE4104 helps organizations reduce operating costs while improving power control and system availability.

Featuring four power outlets in IEC or NEMA socket configurations, the ATEN Eco PDU PE4104 enables administrators to remotely monitor and manage connected devices through a standard TCP/IP network connection. This allows users to control power distribution from virtually anywhere, improving operational efficiency and reducing the need for on-site intervention.

One of the key advantages of the ATEN Eco PDU PE4104 is its advanced remote power control capability. Administrators can remotely switch connected devices on or off, schedule power operations, and configure delayed startup sequences to prevent power inrush issues that may affect system stability. This intelligent power sequencing helps protect equipment and ensures reliable system performance.

The ATEN Eco PDU PE4104 also integrates seamlessly with ATEN eco DC management software, providing an intuitive graphical user interface for centralized device monitoring and configuration. Users can easily manage multiple PDUs, reboot unresponsive devices remotely, and optimize power usage across their infrastructure.

Designed with a slim and compact form factor, the PE4104 supports both rack-mount and desk-mount installations, making it suitable for space-constrained environments where flexible deployment is essential.


Key Features

  • Intelligent 4-outlet power controller
  • Remote power management via TCP/IP
  • Individual outlet power control
  • Power scheduling and delayed startup configuration
  • Prevents power inrush with power sequencing technology
  • Centralized management through ATEN eco DC software
  • Remote device reboot capability
  • Compact and space-saving design
  • Supports rack-mount and desk-mount installation
  • Secure and reliable power distribution
  • Easy deployment in edge computing and retail environments
Function PE4104A PE4104G
Electrical
Nominal Input Voltage 100-120 VAC 100 – 240 VAC
Maximum Input Current 15A(Max), 12A(UL de-rated) 10A(Max)
Input Frequency 50-60 Hz 50-60 Hz
Input Connection NEMA 5-15P IEC C14
Input Power 1800VA(Max) 1440VA(UL de-rated) 2400VA(Max)
Outlet Type (4) NEMA 5-15R (4) IEC 320 C13
Nominal Output Voltage 100-120 VAC 100 – 240 VAC
Maximum Output Current (Outlet) 15A(Max), 12A(UL de-rated) 10A(Max)
Maximum Output Current (Bank) 15A(Max), 12A(UL de-rated) 10A(Max)
Maximum Output Current (Total) 15A(Max), 12A(UL de-rated) 10A(Max)
Breakers Yes(UL1077) Yes(UL1077)
Metering No No
Outlet Switching Yes Yes
Power Consumption AC110V:3.1W:20BTU/h
AC220V:3.5W:22BTU/h

Note:
● The measurement in Watts indicates the typical power consumption of the device with no external loading.
● The measurement in BTU/h indicates the power consumption of the device when it is fully loaded.

AC110V:3.1W:20BTU/h
AC220V:3.5W:22BTU/h

Note:
● The measurement in Watts indicates the typical power consumption of the device with no external loading.
● The measurement in BTU/h indicates the power consumption of the device when it is fully loaded.

Physical Properties
Dimensions (L x W x H) 20.00 x 12.81 x 4.40 cm
(7.87 x 5.04 x 1.73 in.)
20.00 x 12.81 x 4.40 cm
(7.87 x 5.04 x 1.73 in.)
Weight 0.90 kg ( 1.98 lb ) 0.90 kg ( 1.98 lb )
Power Cord Length 3m 3m
Environmental
Temperature (Operating / Storage) 0 – 50℃ / -20 – 60℃ 0 – 50℃ / -20 – 60℃
Humidity (Operating & Storage) 0 – 80% RH, Non-Condensing 0 – 80% RH, Non-Condensing
Compliance
EMC Verification FCC Class A CE-EMC
Safety Verification By request CE-LVD
Note For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format.