PE8324 eco PDU

As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE8324 eco PDUs are intelligent PDUs that contain 24 AC outlets and are available in various IEC socket configurations.

 Connections

• Support 10/100Mbit Ethernet Interface

• Support TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1,V2&V3

• Support 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIOUS

• Support : eco Sensors, Browser ( IE, Firefox, Chrome, Safari )

      Metering

• PDU and outlet level power metering and monitoring

• Environment monitoring — supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring

• Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting

• Support door sensor

      Outlet Switch Control

• Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups

• Outlet group support at the PDU

• Supports multiple power control methods — Wake on LAN, System After AC Back, Kill the Power

• Power-On sequencing, users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the
correct order

• Proactive overload protection(POP) — automatically powers off the last outlet that caused the current overload

Functio0n  PE8324A  PE8324B  PE8324G

 Electrical

 Nominal Input Voltage  100 – 120 VAC  100 – 240 VAC  100 – 240 VAC
 Maximum Input Current  30A(Max); 24A(UL de-rated)  30A Max; 24A (UL de-rated)  32A Max
 Input Frequency  50-60 Hz  50-60 Hz  50-60 Hz
 Input Connection  NEMA L5-30P  NEMA L6-30P  IEC 60309 32A
 Input Power  6240 VA(Max); 4992 VA(UL de-rated)  6240 VA(Max); 4992 VA(UL de-rated)  7360 VA(Max)
 Outlet Type  Total: 24 x NEMA 5-15R
Bank1-1: Outlet 1 – 8; 8 x NEMA 5-15R
Bank1-2: Outlet 9 – 16; 8 x NEMA 5-15R
Bank2: Outlet 17 – 24; 8 x NEMA 5-15R
 Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
 Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
 Nominal Output Voltage  100 – 120 VAC  100 – 240 VAC  100 – 240 VAC
 Maximum Output Current (Outlet)  NEMA 5-15R: 15A(Max); 12A(UL de-rated)  C13: 15A(Max); 12A(UL de-rated)
C19: 15A(Max); 12A(UL de-rated)
 C13: 10A(Max)
C19: 16A(Max); TUV De-rated 15A(Max)
 Maximum Output Current (Bank)  15A(Max); 12A(UL de-rated)  15A(Max); 12A(UL de-rated)  16A(Max); TUV De-rated 15A(Max)
 Maximum Output Current (Total)  30A(Max); 24A(UL de-rated)  30A(Max); 24A(UL de-rated)  32A(Max); TUV De-rated 30A(Max)
 Breakers  2 x 16A UL489 Breaker  2 x 16A UL489 Breaker  2 x 16A UL489 Breaker
 Metering  Outlet Level Current, Voltage, VA, PF, KWh Monitoring  Outlet Level Current, Voltage, VA, PF, KWh Monitoring  Outlet Level Current, Voltage, VA, PF, KWh Monitoring
 Outlet Switching  Yes  Yes  Yes
 Environment Sensor Ports  4  4  4
 Metering Accuracy  Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
 Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
 Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

 Physical Properties

 Dimensions (L x W x H)  177.50 x 6.60 x 4.40 cm
( 69.88 x 2.6 x 1.73 in.)
 177.50 x 6.60 x 4.40 cm
( 69.88 x 2.6 x 1.73 in.)
 177.50 x 6.60 x 4.40 cm
( 69.88 x 2.6 x 1.73 in.)
 Weight  6.33 kg ( 13.94 lb )  6.33 kg ( 13.94 lb )  6.33 kg ( 13.94 lb )
 Power Cord Length  1.6 m  1.6 m  1.6 m

 Environmental

 Temperature (Operating / Storage)  0 – 50°C / -20 – 60°C  0 – 50°C / -20 – 60°C  0 – 40°C / -20 – 60°C
 Humidity (Operating & Storage)  0 – 80% RH, Non-Condensing  0 – 80% RH, Non-Condensing  0 – 80% RH, Non-Condensing

 Compliance

 EMC Verification  FCC Part 15 Class A, Others by Request FCC Part 15 Class A, Others by Request CE, Others by Request
 Safety Verification  By Request By Request CE-LVD, Others by Request

* The specification and pictures are subject to change without notice.
* All trademarks and logos are the properties of their respective holders.