Power |
Operating voltage |
16 to 60 VDC |
Rated current |
0.87 (1.06*) A @ 20 VDC 0.35 (0.43*) A @ 48 VDC |
Inrush current |
40 mA2s @ 20 VDC 257 mA2s @ 60 VDC |
Startup current** |
2x Rated current |
Rated frequency |
DC |
Polarity |
Reverse polarity protected |
Redundant power input |
Yes |
Isolation to |
All other |
Connection |
Detachable |
Connector size |
0.2 - 2.5 mm2 (AWG 24 - 12) |
Shielded cable |
Not required |
|
|
* With 500mA USB load |
|
Interfaces |
Console |
1 x USB Micro-B connector |
USB |
1 x USB 2.0 host interface |
Digital I/O |
1 x 4-ports detachable screw terminal |
Ethernet |
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45 4 x 100/1000 Mbit/s, pluggable connections transceivers supported, Ethernet FX or TX SFP. |
|
|
Temperature |
Operating |
–40 to +70°C (–40 to +158°F) |
Storage & Transport |
–50 to +85°C (–58 to +185°F) |
Maximum surface temperature |
135ºC (275ºF) (temperature class T4) |
|
|
Agency approvals and standards compliance |
EMC |
EN 50121-4, Railway applications – Electromagnetic compatibility – Emission and immunity of the signalling and telecommunications apparatus |
|
EN 61000-6-1, Electromagnetic compatibility – Immunity for residential, commercial and light-industrial environments |
|
EN 61000-6-2, Electromagnetic compatibility – Immunity for industrial environments |
|
EN 61000-6-3, Electromagnetic compatibility – Emission standards for residential, commercial and light industrial environments |
|
EN 61000-6-4, Electromagnetic compatibility – Emission standard for industrial environments |
Safety |
UL/IEC/EN 60950-1, IT equipment |
Marine |
DNV GL rules for classification – Ships and offshore units |
|
|
Dimensional drawing |
Dimension |
134 x 100 x 122 mm (5.25 x 3.93 x 4.80 in) |
Weight |
1.5 kg |
Degree of protection |
IP40 according to EN 60529 |
|
|
Console |
Electrical specification |
USB 2.0 device interface |
Data rate |
High speed 480mbit/s |
Circuit type |
SE LV |
Maximum supply current |
100 mA |
Isolation to |
All other except USB |
Galvanic connection to |
USB |
Connection |
USB Micro-B connector in device mode |
|
|
Protocol and functionality |
WeOS standard - layer 2 protocols and functionality |
IP Host Services |
IP Interfaces (SSL, VPN, GRE) |
IP Routing and VPN |
Static IP Routing, Floating Static Routes, Multinetting, Proxy ARP, Dynamic IP routing (OSPFv2 , RIPv1/v2), VRRPv2/v3, Static Multicast |
SNMP MIB Support (read-only) |
RFC 2787 VRRPv2 MIB, RFC 6527 VRRPv3 MIB |