PowerMAX™ : Gigabit High Speed Ethernet
Cat.6 19” 110/ krone dual type Patch Panel 24 ports, 1U size with color label, Component level
The DINTEK PowerMAX Connectivity solution is comprised of a system of patch panels, work area outlets, and patch cords to enable users to specify the highest level of channel performance available. Our Category 6 patch panels are designed to exceed ANSI/TIA-568-C.2 performance specifications and are backward compatible with lower level cabling products.
DINTEK Category 6 panels support both T568A and T568B wiring schemes and can be terminated with an industry standard 110 or Krone installation tool. Panels include a mounting slot for the DINTEK cable management bar, which easily mounts to the back of the panel, for improved routing and strain releif functionality. Combined with other DINTEK PowerMAX Products, they are the perfect solution to your voice and data communications needs.
Standards
• ISO/IEC11801 2nd edition
• ANSI/TIA Standard 568-C.2
• CENELEC EN 50173
Applications
• 10BASE-T (IEEE 802.3)
• 16Mbps Token Ring (IEEE802.5)
• 100VG-AnyLAN (IEEE802.12)
• 100BASE-T Ethernet (IEEE802.3)
• 155/622Mbps 1.2/2.4 Gbps ATM
• 1000Mbps Gigabit Ethernet
• 550MHz Broadband Video
Features
• Meet ANSI/TIA-568-C.2 Cat.6 component level connecting hardware performance requirements
• Stripped window label for easy management
• 110 and krone dual type IDC termination
• 19” 24 port patch panel, 1U size & 48 port panel, 2U size.
• Accept 22~26AWG, stranded or solid wire
• Modular jack meet FCC part 68
• Wiring: T568A/B
• Optional rear cable management
Environmental Conditions
• Temperature range:
• Storage: -40 to +700C
• Operational: -10 to +600C
• Relative humidity (operational): max. non-condensing 93%
Electrical Characteristics
• Dielectric with standing voltage: 1000V, RMS, 60HZ, 1 MIN.
• Contact resistance: 20 MilliOhms max.
• Current rating: 1.5 AMPS at 200C
Physical Characteristics
• Contact material: Phosphor bronze alloy
• Plate: SPCC-SD 16G
Mechanical Characteristics
• Retention: 30lbs min between the jack and plug.
• Insertion/Extraction life: 750 cycles minimum.
• Number of IDC terminations: 200 minimum.